Power supply and uninterruptible power systems

FH GROUP designs and deploys guaranteed power solutions for IT infrastructure, offices, industrial and commercial facilities: UPS systems, battery systems, inverter solutions, ATS, diesel generators, switchgear and monitoring. Our focus is an engineered architecture, predictable runtime and clear operating procedures.

What we solve →

Typical situations companies come to us with.

Power outages

Emergency and scheduled outages stop the office, checkouts and production. We calculate runtime for your real-world scenario.

Server room protection

Servers and the network must survive a voltage sag and shut down cleanly. We install managed UPS units with alerts.

A generator without automation

There is a generator, but it’s started manually and switched over by guesswork. We set up an ATS and coordinate it with the UPS.

Battery condition unknown

Batteries degrade unnoticed until they fail during an emergency. We set up monitoring and scheduled testing.

Why guaranteed power is needed →

An uninterruptible power system addresses three tasks:

  • protection from voltage sags/spikes and short outages;
  • keeping critical loads running during grid failures;
  • controlled 24/7 operation with defined metrics (runtime, transfer time, redundancy).

What we implement →

UPS systems (modular and monoblock) — Power supply and UPS systems

UPS systems (modular and monoblock)

  • for server rooms, network equipment, workstations and communication nodes;
  • modular UPS for scalable capacity and N+1 redundancy (critical for mid-size and large facilities).
Rack UPS and PDUs — Power supply and UPS systems

Rack UPS and PDUs

  • protection for individual racks, zones or small server rooms;
  • managed PDUs for power distribution, load measurement and basic monitoring.
Diesel generator sets + ATS — Power supply and UPS systems

Diesel generator sets + ATS

  • backup power for prolonged outages;
  • correct transfer logic (ATS), coordination with the UPS, inrush currents and load constraints.
Switchgear and protection — Power supply and UPS systems

Switchgear and protection

  • main/distribution switchboards, automatic transfer, overload and surge protection;
  • readiness for integrating sensors and collecting parameters for remote monitoring.
Energy storage systems (BESS) and hybrid solutions — Power supply and UPS systems

Energy storage systems (BESS) and hybrid solutions

  • battery systems for autonomy and ride-through of critical loads;
  • integration with renewable sources (if needed) and islanding scenarios.
Power monitoring and control — Power supply and UPS systems

Power monitoring and control

  • monitoring UPS units/generators/switchgear, grid parameters, temperature and events;
  • alerts, logs and basic analytics to reduce downtime risk.
Designing an uninterruptible power system

How we approach the project

  1. Load assessment: criticality, consumption profile, inrush currents, runtime requirements (RTO/RPO for IT).
  2. Design: single-line diagrams, redundancy, UPS topology selection (online/double conversion, etc.), coordination with the ATS/generator.
  3. Supply and installation: switchboard work, cable routes, grounding/protection (per design).
  4. Commissioning: load testing, validation of transfer scenarios, operating procedures.
  5. Service: scheduled inspections, battery checks, test transfers, incident tracking.

Useful information →

When power is unstable, the biggest issue isn’t the outage itself — it’s the unpredictability of the consequences: improper shutdown of services, network equipment failures, battery degradation and uncontrolled transfers. A systems approach (UPS + ATS/generator + monitoring) creates a controlled model where risks are measured and reduced, not “discovered” during emergencies.

FH GROUP — IT solutions for business

FAQ →

Didn’t find an answer? Leave a request in the form below or call us: 0 800 40 48 08.

How do you calculate the required UPS capacity?

We take the equipment’s actual consumption, inrush currents and the required runtime, then add headroom for growth. For an accurate calculation, we carry out an on-site load assessment.

How long will the system run without mains power?

As long as the design specifies. For a server room, that might be 15–30 minutes until a clean shutdown; for an office, several hours on batteries or indefinitely with a generator.

Can a UPS be combined with a generator?

Yes, and it’s the most reliable setup. The UPS carries the load while the generator starts, and the ATS switches power automatically.

How often does the system need maintenance?

We recommend scheduled inspections every quarter or six months, battery checks and test transfers. Monitoring reveals problems between inspections.

Can solar panels be connected?

Yes. We integrate battery systems with renewable sources if it makes sense for your facility and set up islanded operation.

Need a UPS or a complete power reliability solution for your facility?

FH GROUP will prepare a technical concept with power sizing, runtime, redundancy and transfer scenarios — followed by implementation and support.